NIST Traceable Certificate available as an option. View Accessories to purchase.
Buying direct from manufacturer: Tax-Free • Unlimited Tech Support • Free Shipping for orders over $250 in contiguous USA!
Description
The DataChart DC1250 is a feature-rich data acquisition system offering 2 universally configurable inputs for measuring DC voltage, DC current, thermocouples, and RTDs as well as frequency and pulse inputs. Four (4) internal alarm setpoints, 2 alarm relay outputs, and 1 digital control input are standard. A maximum storage rate of 100 samples per second can be set for both channels allowing for the capture of short duration process signal anomalies.
The DC1250 is an economical dual input process recorder. CompactFlash cards up to 2 GB in size can be used allowing many data points to be stored over long periods of time. The DC1250 can be used in configuration with many of Monarch's speed measurement sensors; power for sensors is provided from the recorder's rear terminals.
With intuitive operation, flexible input configuration, and versatile standard features, the DataChart DC1250 is a powerful, compact recorder.
Features
A Clear View
The DC1250 has a highly reflective twisted nematic LCD with a bright white LED backlight. The graphic user interface can be configured to display real-time data in a digital or trend format. Configuring the DC1250 is an intuitive process that uses an easy-to-follow menu system.
Versatile Power
The DC1250 is supplied with a universal wall transformer power supply that can operate from 100-240 V ac 50/60 Hz. Interchangeable plugs for UK, EUR, North American, and AUS are also supplied.
Isolated input power of 12-24 V dc is also available for use with instrument power supplies or external batteries. The DC1250’s real-time clock and internal RAM have a battery backup to preserve data in the event of a power loss.
If losing data during a power outage is a concern, the user can add the rechargeable battery pack option. With the battery pack option installed, the DC1250 automatically keeps the rechargeable NiMH batteries charged to capacity. In the event of a power loss, the DC1250 automatically switches over to internal battery power. All functions continue to operate as normal for up to 6 hours! This option is also great for using the DC1250 in areas where no AC or DC power is available.
Ethernet Communication
A rear accessible RJ45 Ethernet port is available. With this option, the DC1250 can be connected to any Standard 10/100BaseT Network. Access and transfer data stored on the compact flash card. View real-time trended data and remotely control and configure recorder with Navigator software. The built-in web server allows real-time data viewing with only an internet browser.
USB Communication
A front-accessible USB port is available. Access and transfer data stored on the compact flash card. View real-time trended data and remotely control and configure recorder with Navigator software. A USB port cannot be ordered with an Ethernet option.
Navigator Software
DataChart® Navigator Software makes reviewing, printing, and exporting data easier than ever. Simply start the program, double-click the data file, and Navigator does the rest. Your data file is displayed in one graphic window complete with the scales as programmed in the DC1250 as well as date and time stamps. You can expand, compress, or use the box zoom to display specific areas of data as needed. The print preview feature allows review prior to printing.
Exporting data is as simple as clicking the Excel™ Icon in the Data table export window. Navigator automatically converts the historic data, starts up Excel™, and loads your data into an organized spreadsheet.
Measure RPM
The DC1250 can be used in conjunction with many of Monarch’s speed measurement sensors. Power for sensors is provided from the DC1250 rear terminals. Measure, display, and record RPM range from 0 - 600,000. Choose the sensor best suited for your application or take your existing signal (0 - 5 V TTL) directly into the DC1250.
Specifications
Input Power Standard
|
9 V dc +/- 0.5V dc @ 5 VA (depends on external loads) provided by external AC wall transformer (provided), non-isolated, 100-240 V ac 50/60Hz | Input Impedance | >100k ohms |
Option |
Isolated 12-24 V dc input power available (not compatible with an internal battery pack option below) | Measurement Rate | Up to 100 samples/sec per channel |
Option |
The internal battery pack provides uninterrupted operation and controlled shutdown during a blackout; 6 V dc, 2400mAH NiMH - Backup time: 8 hours typical (depends on external load) | Math Function | Y=mx + b; average, hi peak, low peak |
DC Sensor Power Output | 2 outputs 5 V dc @ 50 mA to power external sensors | Media | Compact flash to 2GB |
Number of Channels | 2 universal, user-selectable | Display | LCD Graphics, 160 x 80 pixels, black FSTN with white LED backlight; user-controlled backlight level, and contrast adjust (electronic) |
Isolation | 300 V AC/DC channel input to chassis ground | Display Modes | Trending (horizontal), Large dual digital readout, mixed mode |
DC Input |
Voltage Ranges: 0-250 mV; 0-1.25 V; 0-2.5 V, 0-5 V; 0-12.5 V; 0-25 V |
User Interface | 5-button keypad (dual function buttons) |
Accuracy: 0.1% of full scale Resolution: 0.025% of full scale |
Clock | Auto leap year and daylight savings adjustment. Internal battery backup | |
Current Ranges: 0-20 mA; 4-20 mA; 0-50 mA; 10-50 mA |
Relay Output | Two-alarm outputs: 30 V 0.5 A Form A relays | |
Accuracy: 0.1% of full scale excluding 250-ohm external shunt (required) | Opto-isolated Input | One input, 5 to 12 V dc activation @ 10 mA typical | |
Resolution: 0-25% of full scale | Audible | Internal beeper (multiple tones) | |
Thermocouple | Accuracy: 0.3% of full scale (typical). Ambient Temperature Sensor Accuracy: +/-1.5 °C (see datasheet for full specs) | Dimensions | Front panel: 96 mm (1/4 DIN) x 152 mm [3.78 x 3.78 x 6 inches] |
RTD |
Accuracy: 0.3% of full scale (typical) Resolution: 0.1 °C Internal Current source: 1 mA (see datasheet for full specs) |
Environmental |
Indoor Use Only Installation Category II per IEC 664 Pollution Degree Level II per IEC61010-1 Temperature: -10 °C to 50 °C operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperature up to 31 °C, decreasing linearly to 50% relative to humidity at 40 °C |
Frequency Input (Hz) Range | 0-10,000 Hz/ 0-600,000 RPM | Optional | USB: Front-panel USB 2.0 slave port for data and remote real-time display when using navigator software |
Speed Input (RPM) |
Accuracy: Freq: +/-1 Hz; RPM +/1 RPM below 9,999 RPM Input: Low <1.0 V dc; High >3.0 <12.0 V dc Pulse Width: 10-microsecond minimum |
Ethernet: Real-time data display, historic data transfer, remote control, and recorder configuration when using navigator software; built-in web server displays current measured values |
Shipping Codes for the DataChart™ DC1250:
Harmonized Tariff Code: 9030390100
Country of Origin: US
Export Control Classification Number (ECCN): EAR99