WELCOME to the all NEW monarchinstrument.com! • FREE SHIPPING on most orders over $250!

DataChart® DC-6000 Advanced Paperless Data Acquistion System

DataChart® DC-6000 Advanced Paperless Data Acquistion System

PN: DC6000

Regular price $2,495.00 Sale

View Accessories

 

Description

The DataChart 6000 is the most advanced paperless recording system available. It incorporates the latest in measurement, communication, interface and processing technologies to deliver unmatched performance for your data acquisition application. 

The Data Chart 6000 is like no other paperless recorder available. We listened carefully to our product users and developed a device with the unique features they demanded.

Features

  • 6 or 12 universal inputs
  • Up to 4 pulse/frequency inputs
  • 6 or 12 relay outputs
  • Net-workable using standard Ethernet port
  • 21 CFR part 11 compliant (Available option)
  • IP65 rated front panel.
  • 24 Volt DC transmitter power supply
  • On Board Media Drives:  Compact Flash, USB memory stick or external drive, Smart Digital (SD)
  • Touch Screen Control
  • Direct on screen chart annotation with integral stylus
  • Built in OPC and web server.
  • Built in Email Client
  • Shallow installation depth (6.5")

USER INTERFACE AND CONTROL

The DC6000 utilizes a high contrast 5.6 inch color Active Matrix TFT LCD display with a rugged touch screen. Use a finger or the on-bard stylus, if you prefer, to perform data entry and system navigation. The front panel is also fully compliant to IP65 for use in dusty or wet areas. An intuitive icon driven menu system guides the user through easy to follow setup and control screens. The Display builder feature makes setting up custom screens extremely simple. Design up to 50 custom displays containing various combination of indicator types such as horizontal and vertical bar graphs, large and small digital indicators and horizontal or vertical trends. On-screen help is available throughout the menu system to assist you during setup and use.

INTUITIVE MENU SYSTEM

Intuitive Menus

USER CONFIGUREABLE DISPLAY SCREENS

Custom Designable Display Screens

WRITE DIRECTLY ON THE SCREEN

On Screen AnnotationThe innate feature of handwriting notes and comments on the chart of paper recorders had been lost with the onset of video graphic recorders until the arrival of the DC6000. Using the high-resolution touch screen interface and the integral stylus you can once again make notes or comments directly on the chart. This on-screen annotation is stored within the data file directory and can be recalled and displayed on the recorder or in Exhibitor Software.

POWERFUL MATH PACKAGE 

On-board Math PackageThe on-board math package is extremely powerful. It allows the user to input complex polynomial equations using constants, custom functions and variable inputs obtained from live channels. The resultant information can be displayed and recorded as a real time channel. Using the intuitive Calculated Channel Setup menu the user enters in the formula and can perform a test to make sure the formula is accurate.



DATA STORAGE AND SECURITY  

Data Storage and SecurityWhen it comes to storing data, the DC6000 is extremely flexible. Data can be stored to the non-volatile internal flash RAM or any of the available storage drives including CompactFlash™ and USB provided there is media present. Programmable record start and stop times allow the user to start and stop recording at predetermined intervals.Data may also be stored to a remote PC via Ethernet using the optional Exhibitor Software. In addition, the built in OPC Server allows any OPC compliant software client to connect to, communicate with and retrieve data. The DC6000 utilizes many layers of security to protect the integrity of your stored data. All data is stored in an encrypted binary format which prevents data tampering and maximizes compression. The front access media door is lockable to prevent unauthorized access to the internal removable storage media. There are 3 levels of password protection to prevent unauthorized entry into critical recorder function menus. To ensure that data files are completely error free the DC6000 has a built-in rechargeable Nickel Metal Hydride battery backup system that constantly monitors the incoming power source. In the event of a power loss or power dip, the DC6000 seamlessly switches over to the internal power and begins a safe and controlled system shutdown. When power is restored the recorder immediately returns to the last state of operation. This guarantees that data files will never be corrupted by unexpected power conditions.

 

 


21CFR PART 11  (Available Option)

Password ManagementThe DC6000 is fully compliant with the requirements of 21CFR Part 11. This section of the Code of Federal Regulations sets forth the guidelines for handling all aspects of electronic data storage to ensure data is secure and accurate. The DC6000 provides a password management system that allows an administrator to set multiple unique user/password combinations and assign them to one of the 3 available access levels. Each users login password can be set to automatically expire to ensure passwords are regularly updated. The DC6000 also maintains a secure, time stamped audit trail to independently record the date and time of operator entries and actions that create, modify, or delete electronic records.

RECORDING DATA  

Recording DataUsing the Record Setup menu, the user can select which channels to record, the sample storage rate, whether to record alarms and/or events, and the start/stop time and date for the record session. The location of the data file is selected in this menu along with the data file name. The user can also configure the unit to start or stop recording on an alarm level or an externally triggered input.

DATA STORAGE VS. TIME GUIDE 

  1 Channel 2 Channels 4 Channels 6 Channels 12 Channels
Record Rate 64 Meg 1 Gig 64 Meg 1 Gig 64 Meg 1 Gig 64 Meg 1 Gig 64 Meg 1 Gig
10/Sec. 3.1 days 49.4 days 2.5 days 40.8 days 1.9 days 30.4 days 1.5 days 24.2 days 22.5 hours 15 days
5/Sec. 6.2 days 246.9 days 5 days 81.6 days 3.8 days 60.8 days 3 days 48.4 days 1.8 days 30 days
1/Sec. 30.8 days 1.3 years 25.5 days 1.1 years 19 days 303.9 days 15.1 days 241.8 days 9.4 days 150 days
10 Sec. 308 days 13.5 years 251 days 10.6 years 190 days 8 years 150 days 6.4 years 50 days 4.1 years
1 Min. 5.1 years 81.2 years 4.2 years 66 years 3.1 years 49.9 years 2.5 years 39.7 years 1.5 years 24.6 years
10 Min. 50.6 years 811.7 years 42 years 666 years 31 years 499 years 25 years 397 years 15 years 246 years

 

DC6000 Storage Media

Media Storage Locations

Front Accessible: (lockable) 
CompactFlashTM
USB Host (for memory stick) 

Rear Accessible: 
USB Host
Ethernet

Internal:
256 Meg Standard (larger sizes available)


Specifications

DC6000 DimensionsGeneral  Input Resolution: 0.0015% of full scale, 16 bit unless otherwise stated Input Impedance: >1 Mohm Input Channels: 6 or 12 direct input plus 6 additional calculated channels Maximum Input: 50Vdc Isolation: Channel to Channel: 350Vdc or RMS AC                 Channel to Chassis: 2000 Vdc or RMS AC                 Isolation category II: Pollution Degree 2 Measurement Rate: 10 times per second on all direct input channels Common Mode Noise Rejection: >100dB, 50/60 Hz, filter enabled Normal Mode Noise Rejection: >50dB at 50/60 Hz, filter enabled Math Functions: Fully programmable +, -, x, /, square root, sine, cosine, tangent, log, 
totalization, powers, averages, conditional logic; AND, NOT, OR, +, >, <, gated timers. 
Can use live channels in calculation. Can define 6 constants and 6 functions per channel.
  Analog Inputs DC Voltage: +/-125mV, +/-250mV, +/-500mV, +/-1.00V, +/-3.0V, +/-6.0V, +/-12.0V, +/-24.0V Accuracy: Ranges to 1V +/-0.06%, Ranges > 1V +/-0.1%   DC Current:  4-20mA, 0-20mA, 10-50mA Accuracy: +/-0.15% using external 50 ohm 0.1% 1/4 watt shunt   Thermocouple (Per ITS90) Resolution: 0.1C, thermocouple burnout detection: Automatic Reference junction compensation accuracy: +/-0.5 °C (0 °C to 50 °C)   Type       Range (°C) Accuracy (°C)    Range (°F) Accuracy (°F) J              -210 to 0°C +/-1.6 °C              -346 to 32°F +/-3.0 °F                 -0 to 1200 °C +/- 0.7 °C          32 to 2192 °F +/- 1.2 °F
K             -270 to -162 °C +/- 5.0 °C       -454 to -260 °F +/- 9.0 °F                 -162 to -70 °C +/- 2.2 °C         -260 to -94 °F +/- 4.0 °F
                -70 to 1372 °C +/- 0.7 °C         -94 to 2500 °F +/- 1.2 °F
T              -270 to -73 °C +/- 2.5 °C        -454 to -100 °F +/- 4.5 °F                 -73 to 200 °C +/- 1.0 °C          -100 to 400 °F +/- 1.8 °F
E              -270 to -70 °C +/- 2.5 °C        -454 to -94 °F +/- 4.5 °F                 -70 to 1000 °C +/- 0.7 °C        -94 to 1832 °F +/- 1.3 °F
N             -270 to 100 °C +/- 3.0 °C       -454 to 212 °F +/- 5.4 °F                 100 to 1300 °C +/- 0.9 °C        212 to 2372 °F +/- 1.6 °F
S              -50 to 0 °C +/- 2.8 °C              -58 to 32 °F +/- 5.0 °F
                 0 to 1000 °C +/-1.4 °C            32 to 1832 °F  +/- 2.5 °F
                 1000 to 1710 °C +/- 1.1 °C     1832 to 3110 °F +/- 2.0 °F
                 1710 to 1768 °C +/- 1.4 °C     3110 to 3214 °F +/- 2.5 °F
B              0 to 535 °C +/- 4.0 °C             32 to 1000 °F +/- 7.2 °F
                 535 to 1800 °C +/- 2.1 °C       1000 to 3300 °F +/- 3.8 °F
U              0 to 100 °C +/- 0.9 °C              32 to 212 °F +/- 1.6 °F
R              0 to 260 °C +/- 3.0 °C              32 to 500 °F +/- 5.4 °F    
                 260 to 650 °C +/- 1.4 °C          500 to 1200 °F +/- 2.5 °F
                 650 to 1760 °C +/- 1.0 °C        1200 to 3200 °F +/- 1.9 °F
C              0 to 180 °C +/- 2.5 °C               32 to 360 °F +/- 2.5 °F
                 180 to 1200 °C +/- 0.8 °C         360 to 2220 °F +/- 1.5 °F
                 1200 to 2315 °C +/- 3.6 °C       2220 to 4199 °F +/- 6.5 °F
L               -200 to 0 °C +/- 1.1 °C              -328 to 32 °F +/- 2.0 °F
                 0 to 890 °C +/- 0.7 °C                32 to 1650 °F +/- 1.2 °F  

Note: Field calibration improves accuracy to better than +/- 2 °F and up to 
+/- 0.5 °F and ensures compliance with AMS2750D measurement accuracy
requirements for Nadcap accredited suppliers.                   
   
  RTD Base Accuracy: 0.2% or 0.5 °C (1 °F). Resolution: 0.1 °C 2 or 3 wire connection. Cable compensation to +50 ohm. Open and short circuit detection.   Type                               Range °C                        Range °F 100 ohm Plt. 385            -220 to 850 °C                -364 to 1560 °F 100 ohm Plt. 392            -180 to 820 °C                -292 to 1500 °F 200 ohm Plt. 385            -220 to 400 °C                -364 to 750 °F 200 ohm Plt. 392            -180 to 400 °C                -292 to 750 °F 1000 ohm Plt. 385          -200 to 200 °C                -328 to 392 °F 500 ohm Plt. 385            -220 to 850 °C                -364 to 1562 °F 50 ohm Plt. 385              -200 to 850 °C                -328 to 1562 °F 50 ohm Plt. 392              -200 to 1100 °C              -436 to 2012 °F    100 ohm Ni.                    -70 to 300 °C                  -94 to 570 °F 120 ohm Ni.                    -70 to 300 °C                  -94 to 570 °F 1000 ohm Ni.                  -60 to 209 °C                  -76 to 408 °F 10 ohm Cu.                     -70 to 170 °C                  -94 to 338 °F* 50 ohm Cu.426               -50 to 200 °C                  -58 to 392 °F 50 ohm Cu. 428              -200 to 200 °C                -328 to 392 °F 100 ohm Cu. 426            -50 to 200 °C                  -58 to 392 °F 100 ohm Cu. 428            -200 to 200 °C                -328 to 392 °F 100 JIS                           -200 to 649 °C                -328 to 1200 °F                    *0.5% +/- 0.5 °C   Frequency inputs (2 or 4 channels) Range: 0 to 5,000Hz all channels, 0 to 10,000Hz 1 channel (on channels 1, 6, 7 and 12 only) Accuracy: 0.005% +/- 1 digit   Recording Recording Rates: User programmable from 10 samples per second to 1 sample every 24 hours Data Format: Proprietary encrypted format, User file naming Data Storage Capacity: Data stored in non-volatile RAM and recorded automatically to:                 Removable media types:                         CompactFlash™ or USB drive to 16 GB                 Internal media type:                         SD card (secure digital) to 16 GB File Types:Data files, alarm and event files, configuration files, language files, multiple files of different names on a single disk.   Display   Type: Color LED back-lit Active Matrix TFT Liquid Crystal Display Size: 5.6 inch diagonal, Resolution: 320 (W) x 240 (H) pixels Interface: Resistive analog touch screen control Display Builder: Allows user to create custom displays Display Modes: Graphic trending (vertical or horizontal), Bar Graphs (vertical or horizontal), Digital Meter (large or small), Alphanumeric Alarm and Event log Virtual Chart Speed: Programmable from 0.5 inch/hour to 600 inches/hour (10 mm/hr to 10,000 mm/hr) Display Windows: Time/Date, Graphics (bars, large digital, trends) Disk Status, System Status, Menu Button Bar, Unit Identification, Alarms/Events     Communications Network: 10/100 Base T Ethernet per 802.3, RJ45 connection standard Servers: Web server supports http and ftp protocols, OPC server, Modbus over Ethernet server Serial: Isolated RS485/RS232 Modbus Interface (option)   Power Requirements: 100 to 240 Vac, 50/60Hz. 35 VA max. Optional 24 Vdc +/-15% Power Fail Protection: Programmed parameters stored in non-volatile memory. Clock battery backed. Internal battery backup provides orderly shutdown and the ability to survive brownouts and short blackouts (<20 seconds) Power Output: Optional isolated 24Vdc @ 100mA output   Input/Output Digital I/O: 6 or 12 relay outputs, Form A (normally open SPST contacts) rated at 200 Vdc @ 0.5A Max, 2 digital control inputs +5 to +12Vdc @ 20mA (optional), Control inputs may be used for record start/stop, alarm acknowledge and channel reset functions   Safety and Environmental Operating Range: 0 °C to 50 °C, 10% to 80% RH non-condensing Protection: IP65 when mounted in panel Safety: Meets the requirements of EN61010-1 when installed in accordance with the instructions in the manual. EMC: Meets the requirements of EN61326:2003 and CE directive 89/336/EEC.

Weight: Approximately 7 lbs. (3.17 kg) - weight will vary depending on options installed

DC6000 Panel Cuts


 

     

Customer Reviews

Based on 2 reviews Write a review